British Wildlife is the leading natural history magazine in the UK, providing essential reading for both enthusiast and professional naturalists and wildlife conservationists. Published eight times a year, British Wildlife bridges the gap between popular writing and scientific literature through a combination of long-form articles, regular columns and reports, book reviews and letters.
Conservation Land Management (CLM) is a quarterly magazine that is widely regarded as essential reading for all who are involved in land management for nature conservation, across the British Isles. CLM includes long-form articles, events listings, publication reviews, new product information and updates, reports of conferences and letters.
Small, powerful, easy to use and offering many advanced features, loggers from the Tinytag Plus range are the ideal choice for most professional logging applications. The large memory, two programmable alarms, a delayed start time and the ability to offload data whilst still logging all come as standard. The rugged IP68 casing is environmentally sealed, submersible to a depth of 15 m and resistant to most chemicals making this logger suitable for use under most conditions. Ideal for external environmental monitoring.
This is a dual channel device logging temperatures from an internally mounted sensor and an external probe (not included).
To use this logger you will need a PC, a cable, software, and a sensor probe. Please see the accessories tab for probe options.
Internally mounted Temperature Sensor Details:
Range: -25° to +85°C / -40° to +185°F
Sensor Type: 10K NTC Thermistor (encapsulated)
Sensor Location: Internally mounted
Response Time: 25 mins to 95% FSD in moving air
Sensor Accuracy: Between 0° & 40°C: +/- 0.5°C (conservative figure, more details on request)
Resolution: 0.01°C or better
External Temperature Probe Details:
Range: -40° to +125°C / -40° to +257°F
Sensor Type: 10K NTC Thermistor probe
Sensor Location: External probe
Sensor Accuracy: Between 0° & 40°C: +/- 0.5°C (conservative figure, more details on request)
Resolution: 0.02°C or better
Features:
Memory Size: 64k memory chip
No. of Readings: approximately 32,000
Resolution: 16 bit
Trigger Start: Magnetic reed switch
Delayed Start: Relative / Actual up to 45 days
Stop Options: When full / after n readings / never (wrap around)
Reading Types: Actual / Min / Max
Logging Interval: 1 s to 10 days
Offload: When not logging or when logging in minute multiples
Alarms: 2, fully programmable; latchable
Functional Range: -40° to +85°C / -40° to +185°F
IP Rating: IP68 waterproof
Battery Life: Replacement recommended annually
Physical Features:
Case Style: IP68 style
Weight: 110 g
Dimensions of Case: 34 x 59 x 80 mm